EasyManuals Logo

HP P2000 Reference Guide

HP P2000
448 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #335 background imageLoading...
Page #335 background image
HP P2000 G3 MSA System CLI Reference Guide 335
Example
# show enclosures
...
<OBJECT basetype="enclosures" name="enclosures" oid="1" format="rows">
<PROPERTY name="durable-id" type="string">enclosure_0</PROPERTY>
<PROPERTY name="enclosure-id" type="uint8">0</PROPERTY>
<PROPERTY name="enclosure-wwn" type="string">500c0ff0d8b6cb3c</PROPERTY>
<PROPERTY name="name" type="string"></PROPERTY>
<PROPERTY name="location" type="string"></PROPERTY>
<PROPERTY name="rack-number" type="uint8">0</PROPERTY>
<PROPERTY name="rack-position" type="uint8">0</PROPERTY>
drive-
orientation-
numeric
string Numeric equivalents for drive-orientation values.
• 0: vertical
• 1: horizontal
enclosure-
arrangement
string • vertical: Disks are numbered vertically (by column from top to bottom,
proceeding rightward).
• horizontal: Disks are numbered horizontally (by row from left to right.
proceeding downward).
enclosure-
arrangement-
numeric
string Numeric equivalents for enclosure-arrangement values.
• 0: vertical
• 1: horizontal
emp-a-busid string SCSI channel ID of controller A’s EMP.
emp-a-targetid string SCSI target ID of controller A’s EMP.
emp-b-busid string SCSI channel ID of controller B’s EMP
emp-b-targetid string SCSI target ID of controller B’s EMP.
emp-a string Shows the field name EMP A in console format.
emp-a-ch-id-rev string SCSI address and firmware revision of controller A’s EMP.
emp-b string Shows the field name EMP B in console format.
emp-b-ch-id-rev string SCSI address and firmware revision of controller B’s EMP.
midplane-type string Enclosure midplane type.
• 2U12-3G: 2U high, 12 disk slots, 3-Gb disk interface.
• 2U24-3G: 2U high, 24 disk slots, 3-Gb disk interface.
• 2U12-6G: 2U high, 12 disk slots, 6-Gb disk interface.
• 2U24-6G: 2U high, 24 disk slots, 6-Gb disk interface.
• N/A: Not available.
midplane-type-
numeric
string Numeric equivalents for midplane-type values.
• 0: 2U12-3G
• 1: 2U24-3G
• 2: 2U12-6G
• 3: 2U24-6G
enclosure-power string Enclosure power in watts.
pcie2-capable string • Off: Enclosure is not capable of using PCI Express version 2.
pcie2-capable-
numeric
string Numeric equivalents for pcie2-capable values.
• 0: Off
• 1: On
Table 28 enclosures properties (continued)
Name Type Description

Table of Contents

Other manuals for HP P2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP P2000 and is the answer not in the manual?

HP P2000 Specifications

General IconGeneral
Drive SupportSAS
ControllerDual Controller options available
Host Interface6Gb SAS, 8Gb FC, 1Gb iSCSI
RAID LevelsRAID 0, 1, 5, 6, 10
Storage TypeSSD
Hot-swappable ComponentsDrives, controllers, power supplies, fans
Dimensions8.9 x 44.8 x 63.5 cm (3.5 x 17.6 x 25 inches)
Drive BaysUp to 12 LFF or 24 SFF drive bays per enclosure