Parameters link-type FC|iSCSI
Optional; required if the primary-address parameter is not specified. Specifies the type of ports
being used for the inter-system link:
• FC: FC ports.
• iSCSI: iSCSI ports.
max-queue #
Optional. Number of replication images to consider when determining the next image to replicate:
1–64. Used only if the on-collision parameter is set to oldest.
noprompt
Optional in console format; required for XML API format. Suppresses the prompt to revert the
transaction if the command fails, which requires a yes or no response. If this parameter is specified
and the command fails, the transaction is automatically reverted.
nowait
Optional. Adding a volume to a replication set can take the Storage Controller several minutes to
complete. This parameter allows that processing to continue in the background so the Management
Controller can process other commands.
primary-address ip=address|iqn=IQN|wwn=WWN
Optional. Specifies host ports on the local system by IP address, World Wide Node Name, or World
Wide Port Name. An IP address value can include a port number; for example, 10.134.2.1:3260.
Multiple values must be separated by commas and no spaces; for example:
ip=10.134.2.1,10.134.2.2.
priority low|medium|high
Optional. Priority of the replication process on the replication volumes: low, medium, or high.
remote-system system
Optional; required if the remote-vdisk or remote-volume parameter specifies a destination in
a remote system. Name or network-port IP address of the remote system.
remote-vdisk vdisk
Optional. Name or serial number of the vdisk that the remote volume and snap pool should be
created in. If the vdisk is on a remote system:
• You must specify the remote-system parameter.
• If the local and remote MCs can communicate, you can specify a name or serial number;
otherwise, you must specify a serial number.
The snap pool created on the secondary system will be the same size as the snap pool on the
primary system.
remote-volume volume
Optional; do not use with the remote-vdisk parameter. Name or serial number of a
replication-prepared volume to use as a secondary volume. If the volume is on a remote system and
the local and remote MCs can communicate, you can specify a name or serial number; otherwise,
you must specify a serial number.
reserve size[B|KB|MB|GB|TB|KiB|MiB|GiB|TiB]
Optional. Specifies the size of the snap pool to create if the primary volume is a standard volume.
The size value uses the current base, as shown by the show cli-parameters command. The unit
can be specified as follows.
• If base 2 is in use: B (bytes), KiB (kibibytes), MiB (mebibytes), or GiB (gibibytes)
• If base 10 is in use: B (bytes), KB (kilobytes), MB (megabytes), or GB (gigabytes)
If no unit is specified, the unit is 512-byte blocks. If this parameter is omitted, the size will be either
20% of the volume size or the minimum snap-pool size, whichever is larger.

Table of Contents

Other manuals for HP P2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP P2000 and is the answer not in the manual?

HP P2000 Specifications

General IconGeneral
Drive SupportSAS
ControllerDual Controller options available
Host Interface6Gb SAS, 8Gb FC, 1Gb iSCSI
RAID LevelsRAID 0, 1, 5, 6, 10
Storage TypeSSD
Hot-swappable ComponentsDrives, controllers, power supplies, fans
Dimensions8.9 x 44.8 x 63.5 cm (3.5 x 17.6 x 25 inches)
Drive BaysUp to 12 LFF or 24 SFF drive bays per enclosure