HP P2000 G3 MSA System CLI Reference Guide 67
Example Create two unmapped, 100-GB volumes with base name data- in vdisk data, and show the
results:
# create volume-set count 2 size 100GB vdisk data basename data-
Info: The volume was created. (data-000)
Info: The volume was created. (data-001)
Success: Command completed successfully.
# show volume-maps
Volume View [Serial Number (SN) Name (data-000) ] Mapping:
Ports LUN Access Host-Port-Identifier Nickname Profile
-----------------------------------------------------------------
not-mapped all other hosts Standard
Volume View [Serial Number (SN) Name (data-001) ] Mapping:
Ports LUN Access Host-Port-Identifier Nickname Profile
-----------------------------------------------------------------
not-mapped all other hosts Standard
Success: Command completed successfully.
Create ten 20-GB volumes with the base name vd1_v in vdisk vd1, mapped starting with LUN 5
with read-only access through port A1, and show the results:
# create volume-set count 10 size 20GB vdisk vd1 basename vd1_v baselun 5
access ro ports a1
Info: The volume was created. (vd1_v000)
...
Info: The volume was created. (vd1_v009)
Info: The volume was mapped. (vd1_v000)
...
Info: The volume was mapped. (vd1_v009)
Success: Command completed successfully.
# show volume-maps
Volume View [Serial Number (SN) Name (vd1_v000) ] Mapping:
Ports LUN Access Host-Port-Identifier Nickname Profile
-----------------------------------------------------------------
A1 5 read-only all other hosts Standard
Volume View [Serial Number (SN) Name (vd1_v001) ] Mapping:
Ports LUN Access Host-Port-Identifier Nickname Profile
-----------------------------------------------------------------
A1 6 read-only all other hosts Standard
...
Volume View [Serial Number (SN) Name (vd1_v009) ] Mapping:
Ports LUN Access Host-Port-Identifier Nickname Profile
-----------------------------------------------------------------
A1 14 read-only all other hosts Standard
Success: Command completed successfully.

Table of Contents

Other manuals for HP P2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP P2000 and is the answer not in the manual?

HP P2000 Specifications

General IconGeneral
Drive SupportSAS
ControllerDual Controller options available
Host Interface6Gb SAS, 8Gb FC, 1Gb iSCSI
RAID LevelsRAID 0, 1, 5, 6, 10
Storage TypeSSD
Hot-swappable ComponentsDrives, controllers, power supplies, fans
Dimensions8.9 x 44.8 x 63.5 cm (3.5 x 17.6 x 25 inches)
Drive BaysUp to 12 LFF or 24 SFF drive bays per enclosure