:DVM Commands 13
Keysight InfiniiVision DSOX1204A/G Oscilloscopes Programmer's Guide 245
:DVM:FREQuency
(see page 798)
Query Syntax
:DVM:FREQuency?
The :DVM:FREQuency? query returns the displayed 5-digit frequency value that is
displayed below the main DVM value.
If the requirements for the DVM FREQuency mode are not met (see ":DVM:MODE"
on page 246), this query will return 9.9E+37.
Return Format
<freq_value><NL>
<freq_value> ::= floating-point number in NR3 format
See Also • ":DVM:SOURce" on page 247
• ":DVM:ENABle" on page 244
• ":DVM:MODE" on page 246
• ":DVM:CURRent" on page 243