Keysight InfiniiVision DSOX1204A/G Oscilloscopes
Programmer's Guide
27 :TRIGger Commands
Control the trigger modes and parameters for each trigger type. See:
• "Introduction to :TRIGger Commands" on page 585
• "General :TRIGger Commands" on page 587
• ":TRIGger[:EDGE] Commands" on page 597
• ":TRIGger:GLITch Commands" on page 603 (Pulse Width trigger)
• ":TRIGger:PATTern Commands" on page 611 (DSOX1000-Series oscilloscopes
only)
• ":TRIGger:SHOLd Commands" on page 616 (DSOX1000-Series oscilloscopes
only)
• ":TRIGger:TRANsition Commands" on page 622 (DSOX1000-Series
oscilloscopes only)
• ":TRIGger:TV Commands" on page 627
Introduction to
:TRIGger
Commands
The commands in the TRIGger subsystem define the conditions for an internal
trigger. Many of these commands are valid in multiple trigger modes.
The default trigger mode is :EDGE.
The trigger subsystem controls the trigger sweep mode and the trigger
specification. The trigger sweep (see ":TRIGger:SWEep" on page 596) can be
AUTO or NORMal.
• NORMal mode — displays a waveform only if a trigger signal is present and the
trigger conditions are met. Otherwise the oscilloscope does not trigger and the
display is not updated. This mode is useful for low-repetitive-rate signals.
• AUTO trigger mode — generates an artificial trigger event if the trigger
specification is not satisfied within a preset time, acquires unsynchronized data
and displays it.
AUTO mode is useful for signals other than low-repetitive-rate signals. You
must use this mode to display a DC signal because there are no edges on which
to trigger.
The following trigger types are available (see ":TRIGger:MODE" on page 594).
• Edge triggering— identifies a trigger by looking for a specified slope and voltage
level on a waveform.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies InfiniiVision DSOX1204A and is the answer not in the manual?

Keysight Technologies InfiniiVision DSOX1204A Specifications

General IconGeneral
BrandKeysight Technologies
ModelInfiniiVision DSOX1204A
CategoryTest Equipment
LanguageEnglish

Related product manuals