466 Keysight InfiniiVision DSOX1204A/G Oscilloscopes Programmer's Guide
24 :SBUS<n> Commands
:SBUS<n>:CAN Commands
These commands are valid on DSOX1000-Series oscilloscopes when the automotive CAN and
LIN serial decode license (AUTO) is enabled.
Table 70 :SBUS<n>:CAN Commands Summary
Command Query Options and Query Returns
n/a :SBUS<n>:CAN:COUNt:ER
Ror? (see page 468)
<frame_count> ::= integer in NR1
format
n/a :SBUS<n>:CAN:COUNt:OV
ERload? (see page 469)
<frame_count> ::= integer in NR1
format
:SBUS<n>:CAN:COUNt:RE
Set (see page 470)
n/a n/a
n/a :SBUS<n>:CAN:COUNt:TO
Tal? (see page 471)
<frame_count> ::= integer in NR1
format
n/a :SBUS<n>:CAN:COUNt:UT
ILization? (see
page 472)
<percent> ::= floating-point in
NR3 format
:SBUS<n>:CAN:SAMPlepo
int <value> (see
page 473)
:SBUS<n>:CAN:SAMPlepo
int? (see page 473)
<value> ::= {60 | 62.5 | 68 | 70
| 75 | 80 | 87.5} in NR3 format
:SBUS<n>:CAN:SIGNal:B
AUDrate <baudrate>
(see page 474)
:SBUS<n>:CAN:SIGNal:B
AUDrate? (see
page 474)
<baudrate> ::= integer from 10000
to 4000000 in 100 b/s increments,
or 5000000
:SBUS<n>:CAN:SIGNal:D
EFinition <value>
(see page 475)
:SBUS<n>:CAN:SIGNal:D
EFinition? (see
page 475)
<value> ::= {CANH | CANL | RX |
TX | DIFFerential | DIFL | DIFH}
:SBUS<n>:CAN:SOURce
<source> (see
page 476)
:SBUS<n>:CAN:SOURce?
(see page 476)
<source> ::= {CHANnel<n>}
<n> ::= 1 to (# analog channels)
in NR1 format
:SBUS<n>:CAN:TRIGger
<condition> (see
page 477)
:SBUS<n>:CAN:TRIGger?
(see page 478)
<condition> ::= {SOF | DATA |
ERRor | IDData | IDEither |
IDRemote | ALLerrors | OVERload |
ACKerror}
:SBUS<n>:CAN:TRIGger:
PATTern:DATA <string>
(see page 479)
:SBUS<n>:CAN:TRIGger:
PATTern:DATA? (see
page 479)
<string> ::= "nn...n" where n ::=
{0 | 1 | X | $}
<string ::= "0xnn...n" where n
::= {0,..,9 | A,..,F | X | $}