Programming Examples 36
Keysight InfiniiVision DSOX1204A/G Oscilloscopes Programmer's Guide 863
// Set horizontal scale and position.
myScope.DoCommand(":TIMebase:SCALe 0.0002");
Console.WriteLine("Timebase scale: {0}",
myScope.DoQueryString(":TIMebase:SCALe?"));
myScope.DoCommand(":TIMebase:POSition 0.0");
Console.WriteLine("Timebase position: {0}",
myScope.DoQueryString(":TIMebase:POSition?"));
// Set the acquisition type (NORMal, PEAK, AVERage, or HRESolution
).
myScope.DoCommand(":ACQuire:TYPE NORMal");
Console.WriteLine("Acquire type: {0}",
myScope.DoQueryString(":ACQuire:TYPE?"));
// Or, configure by loading a previously saved setup.
byte[] DataArray;
int nBytesWritten;
// Read setup string from file.
strPath = "c:\\scope\\config\\setup.stp";
DataArray = File.ReadAllBytes(strPath);
// Restore setup string.
nBytesWritten = myScope.DoCommandIEEEBlock(":SYSTem:SETup",
DataArray);
Console.WriteLine("Setup bytes restored: {0}", nBytesWritten);
// Capture an acquisition using :DIGitize.
myScope.DoCommand(":DIGitize CHANnel1");
}
/*
* Analyze the captured waveform.
* --------------------------------------------------------------
*/
private static void Analyze()
{
byte[] ResultsArray; // Results array.
int nLength; // Number of bytes returned from instrument.
string strPath;
// Make a couple of measurements.
// -----------------------------------------------------------
myScope.DoCommand(":MEASure:SOURce CHANnel1");
Console.WriteLine("Measure source: {0}",
myScope.DoQueryString(":MEASure:SOURce?"));
double fResult;
myScope.DoCommand(":MEASure:FREQuency");
fResult = myScope.DoQueryNumber(":MEASure:FREQuency?");
Console.WriteLine("Frequency: {0:F4} kHz", fResult / 1000);
myScope.DoCommand(":MEASure:VAMPlitude");
fResult = myScope.DoQueryNumber(":MEASure:VAMPlitude?");
Console.WriteLine("Vertical amplitude: {0:F2} V", fResult);

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies InfiniiVision DSOX1204A and is the answer not in the manual?

Keysight Technologies InfiniiVision DSOX1204A Specifications

General IconGeneral
BrandKeysight Technologies
ModelInfiniiVision DSOX1204A
CategoryTest Equipment
LanguageEnglish

Related product manuals