Commands Quick Reference 4
Keysight InfiniiVision DSOX1204A/G Oscilloscopes Programmer's Guide 99
n/a :WAVeform:XINCrement?
(see page 662)
<return_value> ::= x-increment
in the current preamble in NR3
format
n/a :WAVeform:XORigin?
(see page 663)
<return_value> ::= x-origin
value in the current preamble in
NR3 format
n/a :WAVeform:XREFerence?
(see page 664)
<return_value> ::= 0
(x-reference value in the current
preamble in NR1 format)
n/a :WAVeform:YINCrement?
(see page 665)
<return_value> ::= y-increment
value in the current preamble in
NR3 format
n/a :WAVeform:YORigin?
(see page 666)
<return_value> ::= y-origin in
the current preamble in NR3
format
n/a :WAVeform:YREFerence?
(see page 667)
<return_value> ::= y-reference
value in the current preamble in
NR1 format
Table 36 :WAVeform Commands Summary (continued)
Command Query Options and Query Returns
Table 37 :WGEN Commands Summary
Command Query Options and Query Returns
:WGEN:FREQuency
<frequency> (see
page 672)
:WGEN:FREQuency? (see
page 672)
<frequency> ::= frequency in Hz
in NR3 format
:WGEN:FUNCtion
<signal> (see
page 673)
:WGEN:FUNCtion? (see
page 674)
<signal> ::= {SINusoid | SQUare |
RAMP | PULSe | NOISe | DC}
:WGEN:FUNCtion:PULSe:
WIDTh <width> (see
page 676)
:WGEN:FUNCtion:PULSe:
WIDTh? (see page 676)
<width> ::= pulse width in
seconds in NR3 format
:WGEN:FUNCtion:RAMP:S
YMMetry <percent>
(see page 677)
:WGEN:FUNCtion:RAMP:S
YMMetry? (see
page 677)
<percent> ::= symmetry
percentage from 0% to 100% in NR1
format
:WGEN:FUNCtion:SQUare
:DCYCle <percent>
(see page 678)
:WGEN:FUNCtion:SQUare
:DCYCle? (see
page 678)
<percent> ::= duty cycle
percentage from 20% to 80% in NR1
format
:WGEN:MODulation:AM:D
EPTh <percent> (see
page 679)
:WGEN:MODulation:AM:D
EPTh? (see page 679)
<percent> ::= AM depth percentage
from 0% to 100% in NR1 format

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies InfiniiVision DSOX1204A and is the answer not in the manual?

Keysight Technologies InfiniiVision DSOX1204A Specifications

General IconGeneral
BrandKeysight Technologies
ModelInfiniiVision DSOX1204A
CategoryTest Equipment
LanguageEnglish

Related product manuals