Group 9 Disturbances/Trouble shooting Page 208
Release R1.03e LEIBINGER JET3
Error no. Error message Reason of failure Workaround
1307 Ink delivery is faulty.
Please check pump and all
connections.
Main pump could not place
the membrane to the central
position within 2,5 sec. dur-
ing the normal operation.
Air in the system.
Leakage.
Bleeding valve does not
close correctly.
Main pump is defect elec-
trically.
Main pump is defect mech-
anically.
Activate function perma-
nent bleeding for some
minutes.
Check for leakage
Check bleeding valve and
if necessary replace it.
Check main pump and if
necessary replace it.
1312 Leakage in hydraulic has
been found. Please check
immediately.
Leakage sensor at the ca-
binet bottom reports liquid.
Check system for liquid
and repair.
Check leakage sensor for
dirt and if necessary clean
it.
5030 Stroke-Go error During a stroke has been
generated, the next stroke
output has been already
initiated.
Reduce production speed.
Increase font width.
Use other printing mode
(high speed mode).
Reduce height of total
printing image (Reduce
amount of dots).
5050 Print-Go distance error The printing distance (PG-
distance) which is specified
in the job editor between
two prints is smaller than
the print.
Reduce font width.
Increase the PG-distance
value.
5051 Print-Go error During a print the next
PrintGo-signal has been
already received.
Reduce font width.
Check signal encoder
(sensor).
Check signal encoder for
multi-identification during
a print.
Enlarge product distance.