1 – Warning text 3 – Error text
2 – Count down timer 4 – Button <Quit>
9.3 Error messages
Error no. Error message Reason of failure Workaround
5000 Charging electrode is dirty Charging electrode is dirty. Clean charging electrode
5001 Phasing error Charging electrode is dirty. Clean charging electrode
5002 Error of drop control Charging electrode is dirty.
Wrong frequency has been
set.
Oscillator is defect.
Clean charging electrode
Change frequency
Exchange oscillator
5003 Error of oscillator voltage Bad drop control point.
Charging electrode is dirty.
Wrong frequency has been
set.
Oscillator is defect.
Clean charging electrode
Change frequency
Exchange oscillator
5020 HV-current too high.
Please check deflection
plates for dirt or damp-
ness.
Dirt at the deflection plates.
Dampness at the deflection
plates.
Clean deflection plates
Dry deflection plates
5060 Overload of the charging
voltage amplifier.
Overload of charging voltate
amplifier.
Clean charging electrode
1309 Ink return monitoring
1308 Failure of compression.
Please check compressors
and all connections.
The compressor could not
set the compression within
120 sec.
Check pneum. connections
for leakages. Check com-
pressor and if necessary
exchange it.
Warning messages