EasyManua.ls Logo

Leibinger JET3 - Transport, Installation, and Mounting; Transport, Storage, and Shipping; Mounting Requirements

Leibinger JET3
233 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Group 5 Transport/Start up Page 27
Release R1.03e LEIBINGER JET3
5. Transport/Start up (Putting into service)
5.1 Transport, storage, shipping
In order to avoid damage during transport the following instructions must be observed.
The LEIBINGER JET3 must only be transported in a standing position. It is packed in a
cardboard box with special polystyrene inserts for safe dispatch during delivery.
Transport of the device must only be made in this packing in order to avoid damage.
The printer should be only transported in an empty condition
! A special
draining routine (“ServiceFunctions X Hydraulic X Special Functions/
Tools X Drain Routine“) is available for the draining of the device.
You will find further information in the group Data input/Programming
in the chapter Draining routine!
Note! Storage temperatures below +5°C and above +50°C as well as storage at
outside are not admissible and can lead to damage!
5.2 Mounting
Caution – risk of explosion!
The device must not be operated in rooms where there is a risk of
explosion!
Installation of the device
The device must be installed in a well ventilated room only and must
be kept away from any source of heat, flame or sparks, e.g. radiant
heater, etc..
Check device for damage! When determining a suitable place of setting up, the
necessary additional space requirement for the movement room of the operating and
service personnel must be taken into consideration. Solvents are processed in the
device, adequate room ventilation must be ensured!

Table of Contents

Other manuals for Leibinger JET3

Related product manuals