Group 7 Data/Programming Page 79
Release R1.03e LEIBINGER JET3
7.3.1.3 Interval operation (Set interval time)
The mode <Interval operation> enables the input of start-
and end times when the
LEIBINGER JET3 turns on or off automatically (e.g. 10.20 pm, the device turns on /
10.40 pm, the device turns off). to circulate the ink.
This function prevents that the ink dries up or sediments as well as the jamming of
the nozzle if the printer is turned off for a longer time.
As standard the interval operation is carried out without viscosity control. In case of
need the viscosity control can be also activated for the interval operation.
Attention!
The viscosity control should be only activated for special operating
conditions of the JET3 or after consultation with the LEIBINGER-
service department.
You should set an interval time of at least 20 minutes.
Figure 38
Interval operation (Set interval time)
1 – Menu <Basic Settings> 5 – Example hour block selected
2 – Register card <Interval> 6 – Arrow buttons
3 – Setting field <Interval On> 7 – Control box <Visco control>
4 – Setting field <Interval Off>
2
4
1
6
3
5
Switched on
viscosity control
Switched off viscosity control
7