15 Parameter reference
15.2 Parameter list
868
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00271
C00272
C00273
C00274
C00275
Parameter | Name:
C00271 | SC: Width of current setpoint filter
Data type: UNSIGNED_16
Index: 24304
d
= 5EF0
h
Frequency width of the current setpoint filter at servo control (SC) and sensorless control for synchronous motors
(SLPSM
)
Width around the frequency to be inhibited (C00270
).
Setting range (min. value | unit | max. value) Lenze setting
0.0 Hz 500.0 0.0 Hz
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10
Parameter | Name:
C00272 | SC: Depth of current setpoint filter
Data type: UNSIGNED_16
Index: 24303
d
= 5EEF
h
Damping of the current setpoint filter at servo control (SC) and sensorless control for synchronous motors (SLPSM)
Setting range (min. value | unit | max. value) Lenze setting
0 dB 100 0db
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00273 | Moment of inertia motor
Data type: UNSIGNED_32
Index: 24302
d
= 5EEE
h
Moment of inertia for setpoint feedforward control at servo control (SC) and sensorless vector control (SLVC)
Setting range (min. value | unit | max. value) Lenze setting
0.00 kg cm^2 6000000.00 0.00 kg cm^2
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00274 | SC: Max. change in acceleration
Data type: UNSIGNED_16
Index: 24301
d
= 5EED
h
Limitation of the acceleration change at servo control (SC) and sensorless control for synchronous motors (SLPSM)
Setting in % of M_Nenn per ms.
Setting range (min. value | unit | max. value) Lenze setting
0.0 %/ms 400.0 400.0 %/ms
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10
Parameter | Name:
C00275 | Filter setpoint feedforward control
Data type: UNSIGNED_16
Index: 24300
d
= 5EEC
h
From version 02.00.00
Filter time of setpoint feedforward control at servo control (SC
) and sensorless vector control (SLVC)
The setpoint feedforward control requires the entry of the moment of inertia in C00273
.
Setting range (min. value | unit | max. value) Lenze setting
0.0 ms 1000.0 1.0 ms
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10