126 errors
126 error messages
Error code Description Action
126.xx Low voltage power supply did not detect zero
crossing.
Go to
“Low‑voltage power supply (LVPS)
assembly removal” on page 226.
126.01 Low voltage power supply did not detect zero
crossing.
Go to
“Low‑voltage power supply (LVPS)
assembly removal” on page 226.
133 errors
133 error messages
Error code Description Action
133.1x The black cartridge toner meter cycle (TMC)
switch error:
• .11 recoverable
• .12 nonrecoverable
Go to
“Toner meter sensors (Y, C, M, K) on
TMC card service check” on page 91.
133.2x The cyan cartridge toner meter cycle (TMC) switch
error:
• .21 recoverable
• .22 nonrecoverable
133.3x The magenta cartridge toner meter cycle (TMC)
switch error:
• .31 recoverable
• .32 nonrecoverable
133.4x The yellow cartridge toner meter cycle (TMC)
switch error:
• .41 recoverable
• .52 nonrecoverable
5027
Diagnostic information