4
Operation
Drive batteries
truck. During the run-on time, the green LED
in the push button (1) flashes.
Interrupting charging
DANGER
Disconnecting the battery from the battery charger
during an ongoing charging process poses the risk
of serious personal injury and severe damage to
property. The sparks this generates may ignite
gases formed during the charging process.
Always end the charging process first by shutting off
the external battery charger. Only then disconnect
the connection between the battery and the battery
charger.
In the event of a fan malfunction or fan defect,
any charging process that is currently under-
way is automatically interrupted.
CAUTION
The battery still releases gas following an interrup-
tion of charging.
Leave the battery hood open.
Battery gases in the battery compartment must be
able to dissipate.
External influences may require the charging
process to be manually interrupted.
Switch off the
external battery charger.
Disconnect the battery from the battery
charger.
NOTE
During normal operation, do not terminate
the charging process before the process is
automatically switched off. Early switch-off
during charging results in an insufficiently
charged battery. This diminishes the battery's
capacity.