Loading...
Operation
4
Drive batteries
Charging the battery at the rear
with active ventilation
(version from 08/2017)
2
1
e3871625
3
Active ventilation
Active ventilation ensures that the gases
produced during the charging process when
the battery hood is closed are extracted from
the truck.
DANGER
Risk of explosion! The escaping gases are flamma-
ble.
Only charge the battery in well-ventilated areas.
There must be no objects or obstructions in the
immediate vicinity of the fans. During charging,
ensure that there is sufficient ventilation for the
charge gases to escape.
CAUTION
The battery still r
eleases gas once charging is
complete
To ensure that all remaining gases can escape
from the battery compartment, the rear cover must
remain open during the charging process and also
during the run-on time of the fan.
NOTE
Check the fan for contamination and clean
as required. Check the function of the fan
during each charging process. Malfunctioning
or faulty fans must be replaced immediately.
Contact your service partner.
NOTE
The charging plug for the external battery
charger must be equipped with auxiliary
contacts that are connected to each other via
a jumper. This is required to start the charging
process. Contact your service partner.