Section 8 --- Electrical Systems - House
The Executive 2005
342
The remote control liquid crystal display (LCD) and light emitting diodes (LED) are used for
operation status conditions. The LED lights give inverter status, charge status, battery condition and
error indications at a glance. The LCD screen displays charging cycle status, various meter readings,
automatic generator operation status, programming field and error messages.
The inverter ON/OFF button turns the inverter on or off, and can be used to start or stop the gener-
ator. The up or down arrows are used to scroll up or down through the operation or meter fields. The
up arrow is used to toggle between operation and meter fields. Pressing the up and down arrows will
simultaneously access the programming field. The settings button is used to set or scroll through a par-
ticular programming field.
NOTE:
The main switch on the Inverter/Charger is to remain ON.
Stand-By Operation
The Inverter/Charger can be programmed for stand-by power operation to automatically pro-
vide AC power if shore power discontinues, or the generator is turned off. When AC power resumes,
the inverter will automatically return to "Stand-By" mode and begin charging the batteries.
To Enable Stand-By Mode:
• Momentarily press the blue On/Off button while the motorhome is hooked to shore power
or operating from the generator. The Status light on the remote panel will blink slowly.
Battery charging is not affected in Stand-By mode.
NOTE:
Disable stand-by operation when not in use. House battery power may accidentally be
consumed, causing the house batteries to drain.
Battery Charging with the Inverter
Whether hooked to shore power or operating from the generator, the internal battery charger of the
inverter will automatically charge the batteries when AC power is supplied to the input terminals of the
inverter. The time it takes to charge the batteries to a full state of charge is dependent upon the
inverter set-up parameters and actual state of charge of the batteries.