Section 8 --- Electrical Systems - House
The Executive 2005
338
GENERATOR - AUTO GEN START (RC7 GS)
House batteries operate most of the interior lighting and appliances. As house battery power is con-
sumed, the inverter can be programmed to automatically start and stop the generator to keep up with
the drain on house batteries. A wide field of parameters can be programmed for generator start and stop
points. The settings listed below are an average that should work in most situations. The Automatic
Generator Start feature can be programmed when hooked to shore power, operating from the generator,
or operating from the batteries.
CAUTION:
Disable the automatic generator start program before refueling, during generator
servicing or when storing the motorhome.
INFORMATION:
These instructions are only a guide and not a replacement for the Inverter Owner’s
Manual. Please refer to Inverter Manual for in-depth information.
Entering the Setup Mode:
1. Press the Setup (up and
down arrows) simultaneous-
ly for five seconds then
release. After entering Setup
mode, Search Sense should
display. If this is not dis-
played, press Setup again.
2. Under the Search Sense
heading, Defeat should dis-
play. If not, press Settings
until the inverter is set to
Defeat in the Search Sense
heading.
3. Press Down arrow once,
Auto LBCO will display.
This should be set to ON. If
not, press Settings once.
Auto LBCO should now be
ON.
4. Continue through the rest
of the list using the Down
arrow. Use Setting to change
the value. When the program
is set it may be necessary to
slightly adjust the program
profile to fit a particular
need.
060032h