Chassis Information --- Section 10
The Executive 2005
467
• To extend a particular jack, push and hold the corresponding rocker switch to Extend until
the yellow light goes off. That particular jack is in the level position.
• To retract a particular jack, push and hold the corresponding rocker switch until the jack
fully retracts.
• Turn OFF the Power switch.
• Turn OFF the Ignition switch.
CAUTION:
Damage to the mud flap may occur if the mud flap is located over a raised area when
the suspension is lowered.
CAUTION:
Do not move motorhome while the jacks are still in contact with the ground or
extended, damage to the jacks can occur. Do not use the jacks to raise any wheels
off the ground. Damage to the motorhome may occur.
Automatic Leveling
Automatic Leveling Operation:
The All Jacks Retract mode or Manual mode can be engaged at any time during automatic leveling
operation. Prior to, and during the automatic leveling process, it is essential that there is no movement
in the motorhome.
To begin automatic operation:
Apply the parking brake.
• Turn the ignition switch to ACC.
• Turn the jack control Power switch ON.
• Press the Level switch to AUTO.
• The top green light will start blinking. After a ½ second delay, the pump motor will acti-
vate and all jacks will extend.
The system will attempt to complete the leveling process in one operation. The
motorhome is level when all yellow lights, as well as green lights, go out.
• If leveling is unsuccessful on the first cycle the system will attempt to level four subse-
quent times at seven second intervals.
• If both green lights start flashing alternately, the system has reached maximum extension
on one or more jacks. One or more yellow lights will blink, indicating additional height is
required under one of the jack pads.
• When the leveling process is complete the red warning light will flash, indicating the jacks
are down.
• Turn OFF the jack control Power switch.
• Turn OFF the ignition switch.
WARNING:
When the jacks are extended, a red Jacks Down warning light will blink and the
bong alarm will sound. The alarm will sound if the jacks are down and ignition
switch is turned ON.