Water Systems --- Section 6
The Executive 2005
279
Maintenance
Clean the borosilicate dielectric every 30-60 days. Change the 1st and 2nd stage filters every 3-6
months.
To Clean the Borosilicate Dielectric:
1. Remove cover to expose ozone generator.
2. Gently remove the end of the ozone gas transfer line from the left end of the ozone elec-
trode assembly.
3. Grasp the rounded end of the glass dielectric and pull straight out until it is completely free
from the stainless steel Ozone Electrode Assembly.
4. Moisten a soft cloth or thick paper towel with soapy water and carefully wipe clean any
buildup of the dielectric glass. Dry the glass completely. If the stain on the glass is difficult
to remove, apply a small amount of baking soda to the cloth and clean outside of tube.
CAUTION:
Do not submerge or allow water to enter into the dielectric. If this happens, place the
dielectric on a paper towel in a microwave for one minute or until no moisture is pres-
ent. Wait for dielectric to cool before handling.
5. Wait for the glass dielectric to completely dry. Gently insert the dielectric back into the
stainless steel Ozone Electrode Assembly. Carefully slide the glass dielectric over the
stainless steel rod that is inside the outer shell until it seats at the base.
6. Replace the black ozone transfer tubing over the end of the ozone electrode assembly.
7. Replace the outer unit cover and restore power.
W
ARNING:
Ensure glass dielectric tube is pushed all the way up to the blue line before start-up.
040521g
Inside the Upper Housing with Gas Transfer Line removed.
Glass Dielectric
Ozone Electrode
Assembly
Gas transfer
line