Electrical Systems - House --- Section 8
The Executive 2005
339
Settings:
• Search Sense = Defeat.
Auto LBCO = On.
• Battery Capacity = 500 Amp standard. 1000 Amp All Electric.
• Battery Type = Select Liquid Lead Acid.
• Charge Rate = 100%.
• Shore Power Amps = 30 Amp.
RC7 GS Setup = Personal preference on this. Last key will continuously display the last
screen viewed. In Power Saver mode, the last screen will display for a short period of
time then the screen will go blank.
LCD Contrast = Max Contrast. The screen will fade with each successive contrast selection.
Continue to press Settings until "Max Contrast" appears.
• External Shunt = Select None.
• Fuel Gauge Cutout = 11.8 Volts DC.
Set Clock:
The next group of settings is when, and under what conditions, the generator will start and stop. The
clock must be set before the inverter will allow programming changes to the rest of the menu headings.
Scroll down to the last menu heading Set Clock.
• Hours and minutes will alternately flash every eight seconds.
• Use the Settings button to advance the flashing hours or minutes. The
clock is a 24 hour clock. If the display reads 00:01, it is 12:01 a.m.
If the clock reads 13:00, it is 1:00 p.m.
NOTE:
The clock time and the generator start/stop programming will be
erased whenever the main battery disconnects are turned off.
Programming Auto Start:
After setting the clock, press the UP button to scroll back up to the Menu item Generator Start to
set the conditions at which the generator will automatically start and stop. The following is a general
guide. Use the Up and Down arrows to customize settings.
• Generator Start = 50% State of Charge (SOC).
• Generator Stop = 90% State of Charge (SOC).
• Begin Generator Quiet Time = This is the time when the generator will stop operation.
19:00 is 7:00 PM.
• End Generator Quiet Time = This is the time when the generator can start. 09:00 is 9:00
AM.
• Select Generator = Onan Quiet Diesel.
030970
060032H
Example of a 24 hour clock.