Section 8 --- Electrical Systems - House
The Executive 2005
340
Automatic Generator Start is now programmed. Exit by simultaneously pressing Set-Up buttons.
Waiting for AC, Inverting or a charge status Bulk, Absorb or Float should now be displayed.
When the generator starts from the Auto Start program it will automatically stop at 90% State of
Charge. If the generator started from the Auto Start program, and is still operating at Gen Quiet Time,
the inverter will shut the generator off.
A RED error light flashes and the display will indicate Gen Quiet Time. The fault alarm will sound
for a short time, and can be silenced by pushing the Up or Down button.
NOTE:
To start the generator manually after the Automatic Generator Start feature is
enabled, it must be started from the RC7 GS remote. If the generator is started manu-
ally from any remote switch other than the RC7 GS remote while the Automatic
Generator Start feature is enabled, the inverter may shut the generator off due to the
parameters set.
Starting the Generator Manually:
• Use the RC7 GS remote to start or stop the generator when the Automatic Generator Start
feature is enabled.
• Press the UP or DOWN arrow (while in the main menu) until Generator Start/Stop:
Press (ON/OFF) is displayed.
• Press and hold the ON/OFF button until the generator starts. The display will indicate
the generator was started manually. Use the ON/OFF button or any of the generator
start/stop switches to stop the generator.
To Disable Automatic Generator Operation:
• Set the generator Start and Stop points back to Manual ON/OFF, or switch off the house
and chassis main battery disconnects to erase the clock time and generator start/stop pro-
gramming.