Section 8 --- Electrical Systems - House
The Executive 2005
356
7. Press the DOWN button on the Menu Items button, “End Quiet Time h:m” will display.
End Quiet Time is the time you want the generator to begin operation. Using the Set
Point buttons to set the hour and minute (24 hour clock) will end quiet time.
NOTE:
If desired the quiet time may be disabled. Set the Start and End Quiet Times to the
same hour and minute.
The next set of instructions cover many variables to program the starting or stopping events of the
generator. Many different starting conditions, length of operation or stopping conditions are available. If
in doubt about changing any settings, the factory default settings are average settings and will work in
many situations.
WARNING:
Use caution when programming the automatic generator start function. When this fea-
ture is enabled the generator may start at any time. Disable this feature when per-
forming service to the generator or when stored in an enclosed building.
Gen Auto Start Setup:
8. Press the red and green buttons simultaneously to continue the generator auto-start
programming. Heading number “9 Inverter Setup” should appear.
9. Press the Menu Headings DOWN button to scroll to heading number “12 Gen Auto
Start” setup. Press the Menu Items DOWN button to advance through the next set of
variables. Read all options first before setting any values of the Menu Items in Menu
Heading number “12.”
10. Press the Set Point buttons to change the settings of a Menu Item. Menu Items in Menu
Heading 12 Gen Auto Start Setup:
Set Load Start Amps AC - Starts the generator when the AC current on the pass through relay of the
inverter meets or exceeds the preset number of amps. For example: Setting the preset number of amps to
15 when hooked to a 20 Amp service starts the generator when the total current exceeds 15 Amps on the
pass through relay.
Set Load Start Delay Min - This is the time delay period used with Set Load Start amps AC menu
item. Example: setting the time period to 00:00 starts the generator immediately when the total number
of amps exceeds the setting of menu item Set Load Start amps AC.
Set Load Stop Delays Min - This is the time period the generator continues to operate after the
generator started from the setting in the Set Load Start amps AC menu item.