EasyManua.ls Logo

Monarch NICE1000 - Page 102

Monarch NICE1000
205 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function Code Table NICE1000
new
User Manual
- 100 -
Function
Code
Parameter Name Setting Range Default Unit
Property
FC-04 Designated fault
46: Err46 (Re-leveling
abnormal)
47: Err47 (Shorting door lock
circuit contactor abnormal)
48: Err48 (Door open fault)
49: Err49 (Door close fault)
50: Consecutive loss of
leveling signal
53: Err53 (Door lock fault)
54: Err54 (Overcurrent at
inspection startup)
55: Err55 (Stop at another
landing oor)
57: Err57 (SPI communication
abnormal)
58: Err58 (Shaft position
switches abnormal)
62: Err62 (Analog input cable
broken)
(End)
0 -
FC-05
Designated fault code
(display)
0–9999 0 -
FC-06
Designated fault
subcode
0–65535 0 -
FC-07
Logic information of
designated fault
0–65535 0 -
FC-08
Curve information of
designated fault
0–65535 0 -
FC-09
Set speed upon
designated fault
0.000–1.750 0 m/s
FC-10
Feedback speed upon
designated fault
0.000–1.750 0 m/s
FC-11
Bus voltage upon
designated fault
0.0–999.9 0 V
FC-12
Current position upon
designated fault
0.0–300.0 0 m
FC-13
Output current upon
designated fault
0.0–999.9 0 A
FC-14
Output frequency upon
designated fault
0.00–99.99 0 Hz
FC-15
Torque current upon
designated fault
0.0–999.9 0 A

Table of Contents

Related product manuals