- 100 -
Function
Code
Parameter Name Setting Range Default Unit
Property
FC-04 Designated fault
46: Err46 (Re-leveling
abnormal)
47: Err47 (Shorting door lock
circuit contactor abnormal)
48: Err48 (Door open fault)
49: Err49 (Door close fault)
50: Consecutive loss of
leveling signal
53: Err53 (Door lock fault)
54: Err54 (Overcurrent at
inspection startup)
55: Err55 (Stop at another
landing oor)
57: Err57 (SPI communication
abnormal)
58: Err58 (Shaft position
switches abnormal)
62: Err62 (Analog input cable
broken)
(End)
0 -
●
FC-05
Designated fault code
(display)
0–9999 0 -
●
FC-06
Designated fault
subcode
0–65535 0 -
●
FC-07
Logic information of
designated fault
0–65535 0 -
●
FC-08
Curve information of
designated fault
0–65535 0 -
●
FC-09
Set speed upon
designated fault
0.000–1.750 0 m/s
●
FC-10
Feedback speed upon
designated fault
0.000–1.750 0 m/s
●
FC-11
Bus voltage upon
designated fault
0.0–999.9 0 V
●
FC-12
Current position upon
designated fault
0.0–300.0 0 m
●
FC-13
Output current upon
designated fault
0.0–999.9 0 A
●
FC-14
Output frequency upon
designated fault
0.00–99.99 0 Hz
●
FC-15
Torque current upon
designated fault
0.0–999.9 0 A
●