Description of Function Codes NICE1000
new
User Manual
- 142 -
F6-69 Emergency Evacuation Function Selection
Bit Function Description Default
Bit8
Emergency
running time
protection
If the elevator does not arrive at the required oor after
50s emergency evacuation running time, Err33 is reported.
In this case, the function of switching over shorting stator
braking mode to controller drive based on the time setting
cannot be implemented.
0
Bit9 Reserved - 0
Bit10
Emergency
buzzer output
The buzzer tweets at intervals in the emergency evacuation
running state.
0
Bit12
Shorting stator
braking mode
switched over to
controller drive
It enables the function of switching over shorting stator
braking mode to controller drive.
0
Bit13
Mode of shorting
stator braking
mode switched
over to controller
drive
0
Time setting
If the time of the shorting stator braking mode exceeds
the time set in F6-75, the controller starts to drive the
elevator.
0
1
Speed setting
If the speed is still smaller than the value of F6-72
after 10s in the shorting stator braking mode, the
controller starts to drive the elevator.
Bit14
Emergency
evacuation exit
mode
0
The system exits emergency evacuation when
receiving the door open limit signal from the elevator
that arrives at the target oor.
0
1
The system exits emergency evacuation when
receiving the door close limit signal from the elevator
that arrives at the target oor.
Bit15
Function
selection of
shorting stator
braking mode
When this function is enabled, the setting of related function
codes becomes effective.
0
Function Code Parameter Name Setting Range Default Unit Property
F6-72
Emergency evacuation
switching speed
0.010–0.630 0.010 m/s
It is used to set the switching speed at shorting stator braking mode switched over to
controller drive via speed setting.
Function Code Parameter Name Setting Range Default Unit Property
F6-73 Evacuation parking oor 0 to F6-00 0 -
It is used to set the evacuation parking oor when Bit2 (Stopping at evacuation parking oor)
in F6-69 is enabled.
Function Code Parameter Name Setting Range Default Unit Property
F6-74 Blinking advance time 0.0–15.0 1 s