EasyManuals Logo

Monarch NICE1000 User Manual

Monarch NICE1000
205 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #142 background imageLoading...
Page #142 background image
Description of Function Codes NICE1000
new
User Manual
- 140 -
Table 7-10 Attendant-related functions indicated by bits of F6-67
F6-67 Attendant Function Selection
Bit Function Description Default
Bit0
Calls cancelled after
entering attendant
state
All car calls and hall calls are cancelled after the system
enters the attendant state for the rst time.
0
Bit1
Not responding to
hall calls
The car blinks inside, prompting there is hall call, but
the system does not respond.
0
Bit2
Attendant/Automatic
state switchover
If this function is enabled, the setting of F5-00
(Attendant/Normal switchover time) is valid.
0
Bit3 Door close at jogging
The elevator door closes after the attendant presses the
door close button manually.
0
Bit4 Automatic door close
It is the same as the normal state. After the door open
holding time is reached, the door closes automatically.
0
Bit5
Buzzer tweeting at
intervals in attendant
state
When the hall call oor and the car call oor are
different, the buzzer tweets 2.5s at intervals.
0
Bit6
Continuous buzzer
tweeting in attendant
state
When the hall call oor and the car call oor are
different, the buzzer tweets continuously.
0
Bit7
Car call button
blinking to prompt
When the hall call input is active, the car call button for
the corresponding oor blinks to give a prompt.
0
Function Code Parameter Name Setting Range Default Unit Property
F6-68
Fire emergency
function selection
0–65535 16456 -
Each bit of the function code denes a function, as described in the following table.
If a bit is set to 1, the function indicated by this bit is enabled; if this bit is set to 0, the
function is disabled.
For details on how to view and set this function code in bit, refer to F6-06.
Table 7-11 Fire emergency functions indicated by bits of F6-68
F6-68 Fire Emergency Function Selection
Bit Function Description Default
Bit3
Arrival gong output
in inspection or re
emergency state
The arrival gong is output in the inspection or re
emergency state.
0
Bit4
Multiple car calls
registered in re
emergency state
Multiple car calls can be registered in the re
emergency state. If this function is disabled, only one
car call can be registered.
0
Bit5
Retentive at power
failure in re
emergency state
In the re emergency state, the current system and
car state will be memorized at power failure and be
resumed after the system is powered on again.
0

Table of Contents