- 164 -
After detecting that the output current exceeds (FC-03 x Rated motor current) and the
duration lasts the time specied in the inverse time lag curve, the system outputs a pre-
warning signal.
Function Code Parameter Name Setting Range Default Unit Property
FC-04 Designated fault 0–9999 0 -
●
It is used to designate the fault to be monitored.
The designated fault code is saved in parameters of FC-05 to FC-15, and will not be
overwritten.
Function Code Parameter Name Setting Range Default Unit Property
FC-05 Designated fault code 0–9999 0 -
●
FC-06 Designated fault subcode 0–65535 0 -
●
FC-07
Logic information of
designated fault
0–65535 0 -
●
FC-08
Curve information of
designated fault
0–65535 0 -
●
FC-09
Set speed upon
designated fault
0.000–1.750 0 m/s
●
FC-10
Feedback speed upon
designated fault
0.000–1.750 0 m/s
●
FC-11
Bus voltage upon
designated fault
0.0–999.9 0 V
●
FC-12
Current position upon
designated fault
0.0–300.0 0 m
●
FC-13
Output current upon
designated fault
0.0–999.9 0 A
●
FC-14
Output frequency upon
designated fault
0.00–99.99 0 Hz
●
FC-15
Torque current upon
designated fault
0.0–999.9 0 A
●
Function Code Parameter Name Setting Range Default Unit Property
FC-16 1st fault code 0–9999 0 -
●
FC-17 1st fault subcode 0–65535 0 -
●
FC-18 2nd fault code 0–9999 0 -
●
FC-19 2nd fault subcode 0–65535 0 -
●
···
FC-34 10th fault code 0–9999 0 -
●
FC-35 10th fault subcode 0–65535 0 -
●
These parameters record the latest 10 faults of the elevator.
The fault code is a 4-digit number. The two high digits indicate the oor where the car is