- 81 -
F6 Basic elevator parameters FF Factory parameters
F7 Output terminal parameters FP User parameters
F8 Enhanced function parameters Fr Leveling adjustment parameters
6.3 Function Code Table
Function
Code
Parameter Name Setting Range Default Unit
Property
Group F0: Basic Parameters
F0-00 Control mode
0: Sensorless vector control
(SVC)
1: Closed-loop vector control
(CLVC)
2: Voltage/Frequency (V/F)
control
1 -
★
F0-01
Command source
selection
0: Operation panel control
1: Distance control
1 -
★
F0-02
Running speed under
operation panel control
0.050 to F0-04 0.050 m/s
☆
F0-03
Maximum running
speed
0.250 to F0-04 0.480 m/s
★
F0-04 Rated elevator speed 0.200–1.750 0.500 m/s
★
F0-05 Maximum frequency F1-04 to 99.00 50.00 Hz
★
F0-06 Carrier frequency 0.5–16.0 6.0 kHz
★
Group F1: Motor Parameters
F1-00 Encoder type
0: SIN/COS encoder, absolute
encoder
1: UVW encoder
2: AB incremental encoder
(for asynchronous motor)
0 -
★
F1-01 Rated motor power 0.7–75.0
Model
dependent
kW
★
F1-02 Rated motor voltage 0–440
Model
dependent
V
★
F1-03 Rated motor current 0.00–655.00
Model
dependent
A
★
F1-04 Rated motor frequency 0.00–99.00
Model
dependent
Hz
★
F1-05
Rated motor rotational
speed
0–3000
Model
dependent
RPM
★
F1-06
Encoder initial angle
(synchronous motor)
0.0–359.9 0
Degree
(°)
★