Table 7-4 Meaning of the LED segments for F5-30
No. Segment Meaning of Segment ON
1
A Door 1 open button I/O active
B Door 1 close button I/O active
C Door 1 open delay button I/O active
D Floor 1 door 1 car call I/O active
E Floor 2 door 1 car call I/O active
F Floor 3 door 1 car call I/O active
G Floor 4 door 1 car call I/O active
DP Floor 5 door 1 car call I/O active
2
A Floor 6 door 1 car call I/O active
B Floor 7 door 1 car call I/O active
C Floor 8 door 1 car call I/O active
D Floor 9 door 1 car call I/O active
E Floor 10 door 1 car call I/O active
F Reserved
G Reserved
DP Reserved
3
A Floor 1 door 1 up call I/O active
B Reserved
C Floor 2 door 1 up call I/O active
D Floor 2 door 1 down call I/O active
E Floor 3 door 1 up call I/O active
F Floor 3 door 1 down call I/O active
G Floor 4 door 1 up call I/O active
DP Floor 4 door 1 down call I/O active
4
A Floor 5 door 1 up call I/O active
B Floor 5 door 1 down call I/O active
C Floor 6 door 1 up call I/O active
D Floor 6 door 1 down call I/O active
E Floor 7 door 1 up call I/O active
F Floor 7 door 1 down call I/O active
G Floor 8 door 1 up call I/O active
DP Floor 8 door 1 down call I/O active