- 166 -
Function Code Parameter Name Setting Range Default Unit Property
Fd-03
Number of elevators in
parallel control mode
1–2 1 -
★
Fd-04 Elevator No. 1–2 1 -
★
These two parameters are used to set the quantity and No. of the elevators in parallel
control mode.
Function Code Parameter Name Setting Range Default Unit Property
Fd-05
Parallel control function
selection
Bit0: Dispersed waiting 1 -
★
When Bit0 = 1, the elevator does not return to the base oor; one elevator waits at the base
oor and the other waits at a non-base oor.
Group FE: Elevator Function Parameters
Function Code Parameter Name Setting Range Default Unit Property
FE-00 Collective selective mode 0–2 0 -
★
It is used to set the collective selective mode of the system.
The values are as follows:
•
0: Full collective selective
The elevator responds to both up and down hall calls.
•
1: Down collective selective
The elevator responds to down hall calls but does not respond to up hall calls.
•
2: Up collective selective
The elevator responds to hall up calls but does not respond to hall down calls.