- 172 -
If it is set to any non-zero number, the password protection function is enabled. After a
password has been set and taken effect, you must enter the correct password in order to
enter the menu. If the entered password is incorrect, you cannot view or modify parameters.
If FP-00 is set to 00000, the previously set user password is cleared, and the password
protection function is disabled.
Remember the password that you set. If the password is set incorrectly or forgotten, contact
Monarch to replace the control board.
Function Code Parameter Name Setting Range Default Unit Property
FP-01 Parameter update 0–2 0 -
★
It is used to set processing on the parameters.
The values are as follows:
•
0: No operation
•
1: Restore default settings
•
2: Clear fault records
If you set this parameter to 1 (Restore default settings), all parameters except group F1 are
restored to the default settings. Be cautions with this setting.
Function Code Parameter Name Setting Range Default Unit Property
FP-02
User-dened
parameter display
0: Invalid
1: Valid
0 -
★
It is used to set whether to display the parameters that are modied.
When it is set to 1, the parameters that are different from the default setting are displayed.