- 159 -
FA-39 Floor I/O state 7 (door 2 down call) FA-41 System state
No. Function No. Function No. Function No. Function
0 Reserved 8
Floor 9 down
call
0 Up direction 8 -
1
Floor 2 down
call
9
Floor 10 down
call
1 Down direction 9 -
2
Floor 3 down
call
10
Floor 11 down
call
2
System in running
state
10 -
3
Floor 4 down
call
11
Floor 12 down
call
3 System full-load 11 -
4
Floor 5 down
call
12
Floor 13 down
call
4 System overload 12 -
5
Floor 6 down
call
13
Floor 14 down
call
5 System half-load 13 -
6
Floor 7 down
call
14
Floor 15 down
call
6 System light-load 14 -
7
Floor 8 down
call
15
Floor 16 down
call
7 - 15 -
Function Code Parameter Name Setting Range Default Unit Property
FA-41 System state 0–65535 0 -
★
It displays the current system I/O state.
Group Fb: Door Function Parameters
Function Code Parameter Name Setting Range Default Unit Property
Fb-00 Number of door machine (s) 1–2 1 -
★
It is used to set the number of door machine(s).
Set this parameter based on actual conditions.
Function Code Parameter Name Setting Range Default Unit Property
Fb-01 Opposite door control mode 0–3 0 -
●
It is used to set the opposite door control mode. The values are as follows:
0: Simultaneous control
1: Hall call independent, car call simultaneous
2: Hall call independent, car call manual control
3: Hall call independent, car call independent