NICE1000
new
User Manual Use of the Commissioning Tools
- 53 -
LOCAL/REMOT
Reserved.
FWD/REV
ON indicates down direction of the elevator, and OFF indicates up direction of the
elevator.
TUNE/TC
ON indicates the auto-tuning state.
Unit Indicators
means that the indicator is ON, and means that the indicator is OFF.
Hz
A
V
RPM %
Hz: unit of frequency
Hz
A V
RPM
%
A: unit of current
Hz A
V
RPM
%
V: unit of voltage
Hz A
V
RPM
%
RPM: unit of rotational speed
Hz A
V
RPM
%
%: percentage
4.1.2 Description of Keys on the Operation Panel
Table 4-2 Description of keys on the operation panel
Key Name Function
PRG
Programming Enter or exit Level-I menu.
ENTER
Conrm
Enter the menu interfaces level by level, and conrm the
parameter setting.
Increment Increase data or function code.
Decrement Decrease data or function code.
Shift
Select the displayed parameters in turn in the stop or
running state, and select the digit to be modied when
modifying parameters.
RUN
Run Start the controller in the operation panel control mode.
STOP
RES
Stop/Reset
Stop the controller when it is in the running state and
perform the reset operation when it is in the fault state.

Table of Contents