Description of Function Codes NICE1000
new
User Manual
- 148 -
It is used to set the time that fan and lamp stays ON before being turned off automatically.
If there is no running command in the automatic running state, the system turns off the fan
and lamp automatically after the time set in this parameter.
If this parameter is set to 0, it becomes invalid.
Function Code Parameter Name Setting Range Default Unit Property
F9-02 Motor running time limit 0–45 45 s
It is used to set the running time limit of the motor.
In normal running state, if the continuous motor running time in the same direction between
two adjacent oors exceeds the setting of this parameter but no leveling signal is received,
the system will perform protection.
This parameter is mainly used for over-time protection in the case of steel rope slipping on
the traction sheave.
If this parameter is set to a value smaller than 3s, it becomes invalid.
Function Code Parameter Name Setting Range Default Unit Property
F9-03 Accumulative running time 0–65535 0 h
F9-05 High byte of running times 0–9999 0 -
F9-06 Low byte or running times 0–9999 0 -
These parameters are used to view the actual accumulative running time and running times
of the elevator.
Running times of the elevator = F9-11 x 10000 + F9-12.
Group FA: Keypad Setting Parameters
Function Code Parameter Name Setting Range Default Unit Property
FA-01 Display in running state 1–65535 65535 -
It is used to set the running parameters displayed on the keypad when the elevator is in the
running state.
A total of 16 running parameters can be displayed during running, each respectively
corresponding to the 16 binary bits of FA-01. If a bit is set to 1, the parameter indicated by
this bit is displayed; if this bit is set to 0, the parameter is not displayed.
You can switch over the displayed parameter by pressing
and set whether to display
this parameter according to your own using habit.
The 16 binary bits correspond to the running parameters listed in the following table.
Table 7-13 Running parameters corresponding to 16 bits of FA-01