NICE1000
new
User Manual Description of Function Codes
- 139 -
F6-65 Program control selection 2
Bit Function Description Default
Bit2
Inspection to stop
due to slow-down
During inspection running, if the slow-down switch acts,
the system decelerates to stop.
0
Bit4
Buzzer tweet
during door open
delay
The buzzer will tweet when the door open delay time set
in Fb-13 is reached.
0
Bit8
Door open at
elevator lock
In the elevator lock state, the elevator keeps the door
open at the elevator lock oor.
0
Bit9
Display available at
elevator lock
In the elevator lock state, hall calls are displayed normally. 0
Bit11 Blinking at arrival
The car display blinks when the elevator arrives at a oor.
The blinking advance time is set in F6-74.
0
F6-66 Program control selection 3
Bit Function Description Default
Bit1
Cancelling door
open/close
command at delay
after door open/
close limit
If this function is enabled, the door open/close command
is cancelled at the delay of 1s after door open/close limit.
0
Bit2
Not judging door
lock state at door
close output
On normal conditions, the system determines that the
door is completely closed only when the door close limit
signal is active and the door lock is applied.
If this function is enabled, the system need not judge the
door lock state.
0
Bit3
Door close
command output
during running
The door close command is output continuously during
the elevator running.
0
Bit4
Returning to base
oor for verication
at rst-time power-
on
The elevator runs to the bottom oor for verication at
power-on for the rst time.
0
Function Code Parameter Name Setting Range Default Unit Property
F6-67 Attendant function selection 0–65535 128 -
Each bit of the function code denes a function, as described in the following table.
If a bit is set to 1, the function indicated by this bit is enabled; if this bit is set to 0, the
function is disabled.
For details on how to view and set this function code in bit, refer to F6-06.