- 102 -
Function
Code
Parameter Name Setting Range Default Unit
Property
FC-46
Torque current upon
latest fault
0.0–999.9 0 A
●
Group Fd: Communication Parameters
Fd-00 Local address
0–127
0: Broadcast address
1 -
★
Fd-01
Communication
response delay
0–20 10 ms
★
Fd-02
Communication
timeout
0.0–60.0
0: Invalid
0.0 s
★
Fd-03
Number of elevators in
parallel control mode
1–2 1 -
★
Fd-04 Elevator No. 1–2 1 -
★
Fd-05
Parallel control function
selection
Bit0: Dispersed waiting 1 -
★
Group FE: Elevator Function Parameters
FE-00
Collective selective
mode
0: Full collective selective
1: Down collective selective
2: Up collective selective
0 -
☆
FE-01 Floor 1 display
0000–1999
The two high digits indicate
the display code of the ten's
digit, and the two low digits
indicate the display code of
the unit's digit.
00: Display "0"
01: Display "1"
02: Display "2"
03: Display "3"
04: Display "4"
05: Display "5"
06: Display "6"
07: Display "7"
08: Display "8"
09: Display "9"
10: Display "A"
11: Reserved
12: Reserved
(To be continued)
1901 -
☆
FE-02 Floor 2 display 1902 -
☆
FE-03 Floor 3 display 1903 -
☆
FE-04 Floor 4 display 1904 -
☆
FE-05 Floor 5 display 1905 -
☆
FE-06 Floor 6 display 1906 -
☆