EasyManua.ls Logo

Monarch NICE1000 - Page 106

Monarch NICE1000
205 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function Code Table NICE1000
new
User Manual
- 104 -
Function
Code
Parameter Name Setting Range Default Unit
Property
FE-13
Elevator function
selection 1
0–65535
If the bit is set to 1, the
function expressed is
enabled.
Bit0: Reserved
Bit1: Reserved
Bit2: Re-leveling function
Bit3: Door pre-open function
Bit4: Reserved
Bit5: Forced door close
Bit6: Door open valid at non-
door zone in the inspection
state
Bit7: Door open and close
once after inspection turned
to normal
Bit8: Reserved
Bit9: Independent running
Bit10: Reserved
Bit11: Door re-open after car
call of the present oor
Bit12–Bit15: Reserved
0 -
FE-14
Elevator function
selection 2
0–65535
If the bit is set to 1, the
function expressed is
enabled.
Bit0: Reserved
Bit1: Door open holding at
open limit
Bit2: Door close command
not output upon door close
limit
Bit3: Manual door
Bit4: Auto reset for RUN and
brake contactor stuck
Bit5: Slow-down switch stuck
detection
Bit6–Bit9: Reserved
Bit10: NO/NC output selection
of shorting PMSM stator
contactor
Bit11: Reserved
Bit12: Fan/Lamp output
Bit13–Bit15: Reserved
0 -