- 75 -
Bit
Function
Description
Binary Setting Remarks
Bit4
Startup
compensation
1
Startup torque compensation valid in
emergency evacuation running
When it is set
that the torque
direction is
automatically
calculated,
enable automatic
startup torque
compensation.
Bit8
Emergency
evacuation
running time
protection
1
If the elevator does not arrive at the required
oor after 50s emergency evacuation running
time, Err33 is reported.
This function
is invalid when
the function of
switching over
shorting stator
braking mode to
controller drive is
used.
Bit10
Emergency
buzzer output
1
The buzzer output is active during UPS
emergency evacuation running.
-
Bit12
Shorting stator
braking mode
switched over
to controller
drive
1
Enable the function of switching over the
shorting stator braking mode to controller drive.
-
Bit13
Mode of
shorting stator
braking mode
switched over
to controller
drive
1 Speed setting
If the speed is still
lower than the
value set in F6-72
after the elevator
is in shorting stator
braking mode for
10s, the controller
starts to drive the
elevator.
0 Time setting
If the time of the
shorting stator
braking mode
exceeds the time
set in F6-75, the
controller starts to
drive the elevator.
Bit14
Emergency
evacuation
exit mode
1 Exit at door close limit -
0 Exit at door open limit -
Bit15
Function
selection of
shorting stator
braking mode
1 Enable this function.
When this function
is enabled, the
setting of related
function codes
becomes effective.