WWW.NNC.IR
Macro Reference
351
8
Appendices
Vision System FH/FZ5 Series
User’s Manual (Z340)
TcpClient
TCP Client Normal communication
IoModule identification name
TcpClient
Overview
This is a module is for sending and receiving commands and data by Ethernet TCP Client protocol.
System data
Supported functions
Identification Meaning Initial value
enableDhcp
Enable DHCP
0: Disabled
1: Enabled
0
ipAddress IP address of the system 10.5.5.100
subnetMask Subnet mask 255.255.255.0
defaultGateway Default gateway 10.5.5.110
dns DNS server 10.5.5.1
serverIpAddress Server IP address 10.5.5.101
portNo Port number to receive commands 9600
IoInitialize OK ---
GetPort OK Reference: GetPort (p.542)
PutPort OK Reference: PutPort (p.645)
BusyOut --- ---
JudgeOut --- ---
RunOut --- ---
GetAll OK Reference: GetAll (p.528)
PutAll OK Reference: PutAll (p.643)
ReceiveData OK Reference: ReceiveData (p.651)
SendData OK Reference: SendData (p.696)
SendString OK Reference: SendString (p.698)
ReadPlcMemory --- Reference: ReadPlcMemory (p.649)
WritePlcMemory --- Reference: WritePlcMemory (p.807)
SetPlcData --- Reference: SetPlcData (p.709)
GetPlcData --- Reference: GetPlcData (p.538)