Parker EME
Introduction
192-120100 N16 C3I10T10 - December 2010
Forming the capacitors
Forming the capacitors only required with 400VAC axis controllers and PSUP
mains module
If the device was stored longer than one year, the intermediate capacitors must be
re-formed!
Forming sequence:
ļµ Remove all electric connections
ļµ Supply the device with 230VAC single phase for 30 minutes
ļµ via the L1 and L2 terminals on the device or
ļµ multi axis devices via L1 and L2 on the PSUP mains module
event of storage >1