174 Configuring the Library
7 Select the severity level that will be reported.
Select level 1, “Failed,” to receive only emergency-related notifications. The severity levels are
numbered from 1 to 3, with 3 being the least severe.
If working from the remote client, select multiple severity levels by holding down CTRL and clicking each
choice.
8 Repeat Step 3
on page 171 through Step 10 on page 174 as often as necessary.
9 In the New Email Notification dialog box, click OK.
10 You are finished entering your specifications, click OK on the System Setup Notification dialog box.
Proceed to Enabling Logical Serial Number Addressing for Drives
on page 175
Level Meaning Type of Information Reported
1 Failed Library system has failed
At least one partition (also referred to as a logical library), drive,
or cartridge needs attention
Service ticket has been posted to the LMC
2 Degraded Library system is degraded
Host operations should be possible, but admin should investigate
Service ticket has been posted to the LMC
3 Warning Library system is warning about an issue
Host operations should be possible, but admin should investigate
Service ticket has been posted to the LMC