EasyManua.ls Logo

Quantum Scalar i6000 - Move Media to;from the AMP

Quantum Scalar i6000
384 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Scalar i2000 Installation Guide 269
Adding a 24-Slot I/E Station to an Expansion Module
This section describes how to upgrade an expansion module to include a 24-slot I/E station.
Required tools: #2 Phillips screwdriver, 2.5 mm hex wrench, disposable screw capture tool, wire cutters (for
plastic ties), ESD strap
1 You must export all media from the access door being upgraded.
a. Log into the Library Management Console (LMC).
b. Click Operations Export.
2 Before removing any magazines in the access door of the expansion module you are upgrading,
determine if the magazines are used in any partitions.
3 If the Automatic Teach mode is being used, disable it to perform this upgrade procedure.
4 Remove the magazines in the access door from each partition(s) using the following procedure:
a. Click Physical on the View menu.
b. Click SetupPartitionsConfigure.
The Partitions dialog box is displayed.
c. Select the partition that include the affected magazines and click Modify.
d. Return the affected magazines to the physical pool.
e. Repeat Steps a through d for each partition associated with the access door you are upgrading.
5 Shut down the library.
For more information, see Shutting Down the Library
on page 232.
Note
You can add 24-slot I/E stations to the control module and any of the first seven
expansion modules.

Table of Contents