Scalar i6000 Installation Guide 197
e. The default connection mode for both target and initiator ports is Loop Preferred. For target
ports, other options include Loop and Point to Point. For initiator ports, other options include
Loop and Loop Preferred. Therefore, if you want to change a target port that is set to Point-
to-Point to initiator mode, you cannot do it until you first change the port connection type to
Loop or Loop Preferred. Consult your service representative before making changes to this
setting.
4 After you finish selecting the port configuration settings, click OK.
5 A message appears that asks whether you want to make the change. Click Yes.
Proceed to Configuring FC Host Port Failover
on page 198.