RADWIN2000+SeriesUserManual Release4.2.40 8‐10
ManagerTraps
8.5ManagerTraps
TheRADWINManagerapplicationissuestrapstoindicatevariousevents,displayedinthe
EventsLog.
Table8‐3:RADWINManagerTrapMessages
TrapMessage Severity Remarks
Cannotbindtotrapserviceport.Port
162alreadyinusebyProcessName
(pid:ProcessId)
Warning RADWINManagerwillnotcatchan y
trapsfromtheODU,someother
applicationhasgrabbedthisport.
Deviceunreachable! Error CheckconnectivitytoODU
Connectedto<site_name> Information
<site_name>Sitewillbereset. Information
RestoreFactoryDefaultSettingsin
processonSite<site_name>
Information
FactorySettings:Theprocesswasnot
finishedduetoconnectionissues.
Warning Factorysettingfaileddueto
connectivityproblemtoODU
Reset:Theprocesswasnotfinished
duetoconnectionissues.
Warning Factorysettingfaileddueto
connectivityproblemtotarg et‐ODU
willnotbereset
CannotWritetoMonitorfile.Thereis
notenoughspaceonthedisk.
Warning Freesomespaceondiskonthe
managingcomputerandretry
WindowsError:<error_ID>.Cannot
WritetoMonitorfile.
Warning OperatingSystemerroronthe
managingcomputer
IdenticalIPaddressesat
<local_site_name>and
<remote_site_name>
Warning SetupadifferentIPtoeachsite
TheProductisnotidentifiedatthe
<local_site_name>site.
Warning RADWINManagerisincompatible
withtheODUsoftwareversion
TheProductisnotidentifiedatthe
<remote_site_name>site.
Warning
TheProductisnotidentifiedatboth
sites.
Warning
ProductNotIdentified! Warning