RADWIN2000+SeriesUserManual Release4.2.40 57
OtherLogonOptions
Figure56:LogonwindowwithSNMPv3
IfyouareusingTrapAuthentication,entertheUserandPassword.Leavingthesefieldsblank
orincorrect,wi ll notpreventyoufromloggingon.Youwillnotbeabletoseetrapmessages
directedtothetrapmessageaddressassociatedwithadefineduser.Theallocationand
associationofatrapaddresswithauserisdescribedinManagement.
IfyouareconnectingthroughtheRNMSserverchecktheRNMSconnectbuttonandenter
yourserverIPaddress.
Thefollowingtablesummarizestheseoptions:
TheNetworkManagershouldchangethedefaultpasswordsassoonaspossible,particularly
ifSNMPv3istobeused.
Table52:Usertypes,defaultpasswordsandfunction
UserType
Default
Password
Function
SNMPv1 SNMPv3
Community
Communi
tyString
Password
Default
Value
Observer admin Monitoring ReadOnly public ReadOnly public
Operator admin
Installation,
configuration
ReadWrite netman ReadWrite netman
Installer wireless
Operatorplus
setband
ReadWrite netman ReadWrite netman