RADWIN2000+SeriesUserManual Release4.2.40 94
HSSTypes
Althoughthemasterunitcanbedefinedasoneofthecolocatedradiounits,aGPSsignalcan
alsofurnishasynchronizationsignal.Inthiscase,allthecolocatedunitsareclients,andthe
“masteristheGPSsignalsource.
9.3.2HSSTypes
RADWINofferssev eraltypesofHSS:
SerialHSS
TheRADWINSerialHubSiteSynchronization(SHSS)methodusesanexternalHSSunit
thatisconnectedbetweentheHSSmasterradiounittoallcollocatedradiounits;this
cablecarriesthesynchronizationpulsessenttoeachradiounit,whichsynchronize
theirtransmissionwitheachother.SHSSiscoveredinSerialHubSiteSynchronization.
SHSScanbeusedwiththeRADWIN2000C+andRADWIN2000D+only.
EthernetHSS
TheEthernetHSS(HSSoE)methodconnectsthecolocatedradiounitsviaanethernet
connection.OnecolocatedunitisdefinedastheHSSmaster,anditsendsitssynchro
nizationpulsestotheHSSclientsviatheethernetconnection.HSSoEis covere dinHub
SiteSynchronizationoverEthernet.
GPSHSS
TheGHSSmethodusesaGPSsignalasthemaster,andallcolocatedradiounitsare
definedasclients.FortheRADWIN2000A+,RADWIN2000C+,andRADWIN2000D+,
anadditionalGPSunitisrequiredtoreceivetheGPSsignals.FortheRADWIN2000i,
nosuchunitisrequiredasithasaninternalGPScapability.GHSSiscoveredinGPS
HubSiteSynchronization.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Radwin 2000+ SERIES and is the answer not in the manual?

Radwin 2000+ SERIES Specifications

General IconGeneral
Frequency Bands5.4 GHz, 5.8 GHz
Channel Bandwidth5 MHz, 10 MHz, 20 MHz
EncryptionAES-128
InterfaceEthernet
Operating Temperature-30°C to +60°C
IP RatingIP67