RADWIN2000+SeriesUserManual Release4.2.40 153
PortFunctionality
IngressDirection
Table151:Portsettings‐Ingressdirection
Transparent
Theport‘doesnothingwithregardtoVLANs‐inboundframesareleft
untouched.
Tag
FramesenteringtheRTB(HSU)portwithoutVLANorQinQtaggingare
taggedwithVLANIDandPriority
a
,whicharepreconfiguredbytheuser.
Frameswhicharealreadytaggedatingressarenotmodifiedandpass
through.
a. Priority Code Point (PCP) which refers to the IEEE 802.1p priority. It indicates the frame priority level
from 0 (lowest) to 7 (highest), which can be used to prioritize different classes of traffic (voice, video,
data, etc).
Providertag
FramesenteringtheRTB(HSU)portaretaggedwithprovidersVLANIDand
Prioritywhicharepreconfiguredbytheuser.Frame.swhicharealready
taggedwithProvidertaggingattheingressarenotmodifiedandpassed
through
.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Radwin 2000+ SERIES and is the answer not in the manual?

Radwin 2000+ SERIES Specifications

General IconGeneral
Frequency Bands5.4 GHz, 5.8 GHz
Channel Bandwidth5 MHz, 10 MHz, 20 MHz
EncryptionAES-128
InterfaceEthernet
Operating Temperature-30°C to +60°C
IP RatingIP67