TheSiteSurvey
3.3TheSiteSurvey
3.3.1Introduction
RADWINwirelesslinksmustbeplannedbeforeinstallation. Thedesignatedinstallationsite
mustbeappraisedtodeterminethatthewirelesssystemisabletooperateefficientlyand
provideconnectivitywithoutsignaldegradation.
RADWIN2000+Seriesoffersawideoperatingfrequencyrange.Afreefrequencychannel
mustbedeterminedwithintheoperatingrange,foroptimumperformance.
3.3.2RecommendedEq uipment
Stage1:PreliminarySurvey
Topologicalmapofthearea
Urbanmapofthearea
Compass
Stage2:PhysicalSurvey
100metertapemeasure
Ohmmeter,tocheckgroundconnection
Binoculars
Map
Digitalcamera
Paper,pencil,andaclipboard
GPSdevice(optional)
Compass(optional)
Stage3:RFSurvey
SpectrumAnalyzerwithMaxHoldfunctionandscreencapturefacilitythatcanstore
multipleimages,fordocumentationpurposes
RFaccessories(connectorsandcables)
Communicationdevices(forexample,cellularphones,orasetofwalkietalkies)
3.4Stage1:PreliminarySurvey
Beforevisitingpotentialinstallationsites,asmuchdetailaspossibleshouldbeobtained
aboutthetwodesignatedradioinstallationsitesandtheareabetweenthem.
Toperformapreliminarysurvey:
1. Markthetwodesignatedinstallationsitesonatopographicmapofthearea.
2. Measurethedistancebetweenthesites;checkthatitiswithinthespecifiedrange
oftheequipment.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Radwin 2000+ SERIES and is the answer not in the manual?

Radwin 2000+ SERIES Specifications

General IconGeneral
Frequency Bands5.4 GHz, 5.8 GHz
Channel Bandwidth5 MHz, 10 MHz, 20 MHz
EncryptionAES-128
InterfaceEthernet
Operating Temperature-30°C to +60°C
IP RatingIP67