ConfiguringFalseRadarMitigation
FalseRadarMitigationhastwocomponents:
1. Reductionoffalsepositiveradardetectionbyreductionoftheprobabilityofdetectingany
kindoffalseradars,whileallowingthesystemtodetectrealradarsignals.
2. Eliminationofdetectionofspecificfalseradartypesbyblockingdetectionoffalseradars
ofaspecifictype.Therearethreetypesofradars:
•Fixed:Falseradarswithfixedpulsewidthhavingfixedrepetitionfrequency
•Variable:Falseradarswithvariablepulsewidthhavingvariablerepetitionfrequency
•Staggered:Falseradarswithvariablerepetitionfrequencywithinaburstperiod
(Appliesto5.4GHzETSIonly)
17.4ConfiguringFalseRadarMitigation
TheconfigurationmethodfortheMasterODU(ETSIandFCC/IC)isthesameasfortheSlave
ODU(ETSIonly).WewilldemonstratetheMasterODUforalinkusingthe5.3GHzFCC/IC
band:
ToconfigureFalseRadarMitigation:
1. LogontotheMasterODUasInstaller.
2. EntertheConfigurationwindowandopentheAdvancedtab.