ToolsRequiredforInstallation
4.4ToolsRequiredforInstallation
ThefollowingisalistoftheequipmentandmaterialsrequiredtoinstallRADWIN2000+Series
hardware.
4.4.1ToolsandMaterials
CrimpingtoolforRJ45(iftheODUPoEcableiswithoutconnectors)
Spanner/wrench13mm(½”)
Drill(forwallmountingonly)
Cableties
Sealingmaterial
WaterproofingtapesuchasScotch23Tape¾”wide,from3MtoensureIP67compliant
protectionagainstwateranddust
4.4.2Cablesandconnectors
ODUgroundingcable10AWG
ODUPoEcable(outdoorclass,CAT5e,4twistedpairs,24AWG):
Upto100m.for100BaseTconnection.
Fora1000BaseTconnection(HBSonly)useanODUPoEcablenolongerthan75m.
ExternalCAT5ecablediametershouldbebetween79mmtoensur
ewaterproof
sealing.
4.5UnpackingandChecking
Foreachitem:
1. Removetheequipmentfromthebox.
2. CheckthateverythinglistedontheincludedBillofMaterialsorProformaInvoiceis
present.
3. Ifanyitemismissing,contactCustomerService.Youwi ll beadvisedwhetherto
returnthepackageforreplacement,orwhetherthemissingitemcanbesupplied
separately.
4. Donotdisposeofthepackaginguntiltheunitisinstalledandoperational.
For1000BaseT,youshoulduseRADWINsuppliedODUPoEcables,which
guarantees1Gbperformance.RADWINcannotguarantee1Gb
performanceifyouusethirdpartycables.